-> Transmission Configuration.
There are several configuration in transmission or microwave in telecommunication like :

- Unprotected 1+0
In this configuration there are only one Antenna, One Radio/ODU/RAU and One Modem
Unit for traffic.
If any trouble with radio or modem this hop will be down, because there isn’t
protect by other equipment.




- Protected 1+1
If any trouble in one of radio or modem this hop will be protected by other equipment.
i.e. If Radio/ODU 1 faulty so Modem 1 will be down. In this case the traffic capacity will be move to Radio/ODU 2 and Modem 2 automatically.
There are two(2) type for this configuration :

1. Hot Standby.
In this configuration there are only one Antenna, Two(2) Radio/ODU/RAU and
Two(2) Modem Unit for traffic.



2. Space Diversity
In this configuration there are Two (2) Antenna, Two(2) Radio/ODU/RAU and
Two(2) Modem Unit for traffic.



To Pointing or Aligment this configuration, use this rule :
- Step A: Pointing done only between RAU RAU 1A and 1B (RAU RAU 2A & 2B off).
- Step B: Pointing only RAU RAU 2A with 1B (only moving RAU 2A, 1A & RAU RAU 2B off).
- Step C: Pointing only with RAU RAU 2B 1A (only moving RAU 2B, 1B & RAU RAU 2A off).